Comparison of Enthalpy Method and Water Fraction Method to Mathematically Model Water Vaporization During RF Ablation

Authors

  • Yuliia Fatieieva Zaporizhzhye National University
  • Pedro Almendárez Universidad Autónoma de San Luis Potosí
  • Ricardo Romero-Méndez Universidad Autónoma de San Luis Potosí
  • Enrique Berjano Universitat Politècnica de València
  • Macarena Trujillo Universitat Politècnica de València

Keywords:

Enthalpy method, Mathematical modeling, Radiofrequency ablation, Tissue dehydration, Water vaporization.

Abstract

During high-temperature energy-based therapies such as radiofrequency ablation (RFA) the target tissue reaches temperatures around 100ºC, which causes tissue dehydration by water vaporization. In order to be as realistic as possible, RFA theoretical models should include the formulation of these phenomena. There are currently two fixed mesh methods of modeling the electrical and thermal effects produced by water vaporization: the enthalpy method and the water fraction method. Our objective was to compare both methods, especially to assess the thermal and electrical performance in terms of electrical impedance progress during heating, distributions of temperature, and temperature progress at some specific locations. The results showed the performance of both methods to be qualitatively analogous, with similar impedance progress, temperature distributions and temperature progress. They were hence equally able to mimic the thermal and electrical performance in a pulsed protocol, i.e. during the period without applying RF power. The main difference between the methods was the time at which impedance started to rise. All these findings suggest that the two methods offer equivalent results in RFA modeling. However, since the enthalpy method has one less problem to be solved (dynamic volume fraction of liquid water in the tissue) it is less complex, has a lower computational cost and therefore seems to be more suitable for modeling RFA with dry or internally cooled electrodes, i.e. those in which there is no interstitial saline infusion. However, the water fraction method would be more appropriate in the case of RFA with externally irrigated electrodes.

Author Biographies

Yuliia Fatieieva, Zaporizhzhye National University

Zaporizhzhye

Pedro Almendárez, Universidad Autónoma de San Luis Potosí

Ingeniería

Ricardo Romero-Méndez, Universidad Autónoma de San Luis Potosí

Ingeniería

Enrique Berjano, Universitat Politècnica de València

Electronic Engineering

Macarena Trujillo, Universitat Politècnica de València

Matemática Pura y Aplicada

Downloads

Published

2014-10-17

Issue

Section

Articles